Stent Graft Advancement in Gothic Arch
For advancing stent grafts through sharply angulated (gothic) aortic arches, use a through-and-through (T&T) guidewire technique with snare assistance from a femoral or carotid access to provide directional control and prevent device prolapse during deployment.
Primary Technical Approach
The most effective strategy for navigating severe arch angulation involves creating enhanced wire support and directional control:
Through-and-Through Wire Technique
- Establish a T&T wire between two access sites (typically carotid-femoral or transseptal-femoral) to create a stable rail that prevents upward prolapse of the delivery system in the arch 1, 2
- This technique allows simultaneous pushing from the groin while pulling down on the delivery system, moving the wire and device as a unit through the angulated arch 2
- The T&T wire can be maintained until the desired position is reached, then released after deployment 3
Snare-Assisted Advancement
When standard wire techniques fail:
- Advance a snare from the contralateral femoral artery to catch the distal end or nose cone of the stent graft 4, 5
- Pull the device through the angulated arch while simultaneously pushing from the delivery site 5
- This is particularly effective when the aortic arch angle causes recurrent upward prolapse of the delivery system 2
Alternative Techniques for Specific Anatomies
Ascending Aorta Loop Formation
For extremely tortuous anatomy where valve crossing must be avoided:
- Create a carotid-femoral T&T wire with loop formation in the ascending aorta 3
- The nose-tip of the endograft curves over the looped guidewire pointing toward the innominate artery without crossing the aortic valve 3
- This provides T&T support without requiring transapical access in frail patients 3
Transseptal Access with Snare Pull-Down
For cases with recurrent device prolapse:
- Obtain antegrade ascending aortic access through a transseptal sheath 2
- Stabilize the sheath with an indwelling transseptal guidewire held taut by a snare in the descending aorta 2
- Use a second snare through the transseptal sheath to pull down on the stiff delivery guidewire 2
Critical Technical Considerations
Landing Zone Optimization
Creating an optimal straight landing zone is essential for current stent graft technology 6. The guidelines emphasize:
- Hybrid approaches with arch debranching can create a proximal landing zone in Dacron graft when native anatomy is unsuitable 6
- For purely endovascular approaches, a sufficient proximal landing zone of at least 2 cm is required 7
- Stent graft diameter should exceed the landing zone diameter by 10-15% 7
Deployment Control
During actual deployment in angulated arches:
- Reduce blood pressure pharmacologically (nitroprusside or adenosine to <80 mmHg systolic) or use rapid right ventricular pacing to prevent downstream displacement 7
- Consider early tip capture release and push-up technique: release the proximal bare stent early, then perform a push-up maneuver after landing the proximal edge to conform to aortic morphology 8
- Use intraoperative fluoroscopy to precisely identify and evaluate landing zones 6
Imaging Guidance
Transesophageal echocardiography (TOE) or intravascular ultrasound (IVUS) can be invaluable for:
- Identifying correct position of the guidewire within the true lumen in dissection cases 7
- Confirming device position before final deployment
- Fixed imaging systems are beneficial for advanced endovascular arch techniques 6
Common Pitfalls to Avoid
Device Selection
- Avoid devices with large nose cones when using directional tip control techniques—these work best with streamlined delivery systems 1
- Ensure delivery system French size is compatible with iliofemoral access (typically 14-24F required) 7
Anatomic Contraindications
- Ascending aortic diameter >40 mm increases risk of retrograde type A dissection 6
- Avoid hybrid/endovascular arch repair in connective tissue disorders unless landing zones are in Dacron-replaced aorta 6
- Angulation >60° of the proximal neck significantly increases risk of device migration and endoleak 7
Stroke Risk
Stroke remains a significant complication (up to 11.5% in total endovascular arch repair) 6. Minimize this by:
- Careful wire manipulation to avoid embolization
- Limiting catheter exchanges in the arch
- Consider cerebrospinal fluid drainage in high-risk patients 7
When to Abandon Endovascular Approach
If T&T wire and snare techniques fail, or if anatomic features are prohibitive, consider hybrid repair with surgical debranching to create a suitable landing zone 6. This is particularly appropriate for:
- Patients too high-risk for conventional open repair who meet specific anatomic criteria 6
- Diffuse aneurysms involving ascending aorta, arch, and descending aorta (mega aorta) 6
- Young patients or those with connective tissue disorders where long-term durability is paramount 6
The frozen elephant trunk technique—open arch replacement with antegrade stent graft placement under direct vision during circulatory arrest—provides the most controlled deployment in severely angulated anatomy when endovascular access proves impossible 6, 9.