Dorsal Approach to the Distal Radius: Surgical Technique
The dorsal approach to the distal radius is performed through a longitudinal incision over the dorsal wrist, typically between the first and second or deep to the fourth extensor compartments, allowing direct visualization and reduction of dorsally displaced or impacted articular fragments that are difficult to address through a volar approach.
Indications for Dorsal Approach
This approach is specifically indicated for:
- Dorsally impacted articular surface fractures where volar plating cannot adequately visualize or reduce the fragments 1
- Dorsal comminution patterns requiring direct visualization 2
- Dorsoulnar corner (DUC) fragments that are challenging to capture with standard volar fixation 3
- Radial styloid-dominant patterns with large lateral column fragments 4
Surgical Technique
Incision and Exposure
- Make a single longitudinal dorsal incision over the distal radius 2
- Position the incision to access between the first and second dorsal compartments or deep to the fourth compartment 5
- For radial column fractures, a modified Kocher-style dorsolateral approach (approximately 5 cm) provides excellent access to the radial styloid 4
Reduction and Fixation
- Perform arthrotomy to directly visualize the articular surface 2
- Achieve anatomic reduction under direct vision
- Stabilize with 2.4 mm locking plates positioned between compartments to minimize tendon irritation 2
- For radial styloid patterns: buttress with a distal radius T-plate and compress using 3.0 mm cannulated compression screws placed from the radial styloid across the fracture 4
- For DUC fragments: consider arthroscopic-assisted reduction with locked, hooked K-wires for low-profile dorsal fixation 3
Clinical Outcomes
Studies demonstrate satisfactory medium-term results 5:
- Congruous articular reduction achievable in all cases with direct visualization
- Range of motion typically reaches 82% of contralateral side 2
- Mean grip strength approximately 30 kg 2
- No tendon ruptures reported in properly positioned hardware 2, 5
Critical Caveats
Hardware prominence and removal: Approximately 50% of patients may require plate removal due to discomfort from extensor tendon irritation 2. Position plates carefully between compartments to minimize this risk.
Osteoarthritis risk: Early symptomatic osteoarthritis develops in some patients with high-energy intra-articular fractures, regardless of approach 2, 5. This reflects injury severity rather than surgical technique.
Patient selection is crucial: The dorsal approach is not a replacement for volar locking plating in most distal radius fractures 4. Reserve this technique for specific fracture patterns where dorsal comminution, impaction, or fragment morphology makes volar fixation inadequate.