What does an intrinsic amplitude of 23.5mV for a ventricular lead with automatic settings of 0.8 volts (V) at 0.4 milliseconds (ms) indicate?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: June 24, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

From the Research

The intrinsic amplitude of 23.5mV for a ventricular lead with automatic settings of 0.8V at 0.4ms indicates excellent lead function with appropriate safety margins. This finding suggests that the pacemaker is correctly sensing the heart's natural electrical activity and has been programmed with appropriate output settings. The high intrinsic amplitude (23.5mV) demonstrates good contact between the lead and the ventricular myocardium, ensuring reliable sensing of the heart's intrinsic activity, as supported by a study on ventricular sensing in transvenous cardiac implantable electronic devices 1. The automatic output settings of 0.8V at 0.4ms represent the pacing threshold, which is significantly lower than the sensing value, providing an adequate safety margin. This relationship is important because it ensures the pacemaker will reliably capture the ventricle when pacing is needed while using minimal battery energy. Some key points to consider in the management and interpretation of pacemaker lead function include:

  • The potential for lead failure and the importance of monitoring for signs of malfunction, such as oversensing or inappropriate shocks, as discussed in studies on lead failure and home monitoring 2, 3.
  • The role of home monitoring in early detection of lead-related issues and prevention of adverse events, as highlighted in a study on the potential role of home monitoring 3.
  • The feasibility of using left ventricular leads for sensing in certain clinical situations, as explored in a study on left ventricular sensing 1. The substantial difference between the sensing value and pacing threshold indicates the lead is well-positioned and functioning properly, which should translate to consistent pacemaker performance and extended battery life. Overall, the provided intrinsic amplitude and automatic settings suggest a well-functioning ventricular lead with appropriate safety margins, which is crucial for effective and safe pacemaker operation, as generally supported by the principles outlined in various studies on pacemaker lead function and management 2, 4, 5, 3, 1.

References

Research

Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure.

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2009

Research

Oversensing from electrode 'chatter' in a bipolar pacing lead: a case report.

Pacing and clinical electrophysiology : PACE, 1990

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.