How reliable is the Eko 3-lead Electrocardiogram (EKG) stethoscope and reader?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: August 14, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Reliability of the Eko 3-Lead ECG Stethoscope and Reader

The Eko 3-lead ECG stethoscope and reader demonstrates good accuracy for specific applications like rhythm detection and QRS morphology assessment, but has limitations that make it insufficient as a standalone diagnostic tool for comprehensive cardiac evaluation.

Technical Reliability and Accuracy

The reliability of any ECG device depends on several critical technical factors:

  • Lead Placement Accuracy: Proper lead placement is crucial for ECG interpretation. The American College of Cardiology emphasizes that variation in precordial lead placement of as little as 2 cm can result in significant diagnostic errors, particularly for anteroseptal infarction and ventricular hypertrophy 1.

  • Signal Quality: The American Heart Association notes that inadequate bandwidth settings can distort waveforms, reduce reproducibility, and blur the distinction between normal and abnormal tracings 2.

  • Comparison to Standard 12-Lead ECG: Research comparing the Eko DUO (precordial lead) to standard 12-lead ECG showed:

    • 84% accuracy in QRS morphology classification 3
    • 70% accuracy in QTc duration measurement (within 40ms of standard) 3
    • Systematic underestimation of QTc intervals 3

Specific Applications and Limitations

Strengths

  • Heart Sound Recording: The Eko system demonstrates high agreement with in-person auscultation findings and echocardiogram results for heart sound evaluation 4.
  • Rhythm Detection: The device shows promise in rhythm detection, particularly for atrial fibrillation 3.
  • Ease of Use: Most cardiologists in studies found the system easy to use and would consider using it in clinical settings 4.

Limitations

  • Reduced Diagnostic Information: Single-channel or limited-lead ECGs contain less diagnostic information than standard 12-lead ECGs 5.
  • ST-Segment Analysis: Consumer ECG devices, including multi-lead systems like Eko, cannot currently reliably detect ST-segment deviations that might indicate myocardial infarction or ischemic episodes 5.
  • QTc Measurement: The device shows only 70% accuracy in QTc duration measurements compared to standard ECG 3.

Clinical Implications

The reliability of the Eko 3-lead ECG has important clinical implications:

  • Screening Tool: The device may be useful as a screening tool for detecting rhythm abnormalities and basic QRS morphology assessment 3, 4.

  • Not a Replacement for 12-Lead ECG: For comprehensive cardiac evaluation, especially for diagnosing conditions like myocardial infarction, ventricular hypertrophy, or conduction disorders, a standard 12-lead ECG remains necessary 2, 5.

  • Potential for Misdiagnosis: Reliance on limited-lead ECG devices could lead to missed diagnoses or misdiagnosis if used as the sole diagnostic tool 2.

Best Practices for Use

To maximize reliability when using the Eko 3-lead ECG:

  • Ensure Proper Placement: Follow manufacturer guidelines for electrode placement, recognizing that even small deviations can affect results 1.

  • Regular Training: Personnel using the device should receive periodic retraining in proper lead positioning 2.

  • Physician Overreading: Computer-based interpretation of ECGs should always be considered an adjunct to physician interpretation, not a replacement 2.

  • Confirm Abnormal Findings: Any abnormal findings should be confirmed with a standard 12-lead ECG before making clinical decisions 2.

  • Use Within Scope: Recognize the device's strengths (rhythm detection, basic QRS assessment) and limitations (ST-segment analysis, precise interval measurements) 3, 5.

Conclusion

The Eko 3-lead ECG stethoscope demonstrates reasonable reliability for specific applications like rhythm detection and basic QRS morphology assessment. However, its limitations in lead configuration, measurement accuracy, and diagnostic capabilities make it insufficient as a standalone diagnostic tool for comprehensive cardiac evaluation. It should be viewed as a useful screening and monitoring tool that complements, rather than replaces, standard 12-lead ECG evaluation for definitive diagnosis.

References

Guideline

Electrocardiogram Lead Placement Guidelines

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Research

Review of current ECG consumer electronics (pros and cons).

Journal of electrocardiology, 2023

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.