What is the correct CPT (Current Procedural Terminology) code for replacing the battery in a dual chamber permanent pacemaker?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: August 17, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

CPT Code for Dual Chamber Permanent Pacemaker Battery Replacement

The correct CPT code for replacing the battery in a dual chamber permanent pacemaker is 33228.

Understanding Pacemaker Battery Replacement Coding

When coding for pacemaker battery replacement (also called generator replacement), the code selection depends on the type of pacemaker system:

  • 33227: Single chamber pacemaker generator replacement
  • 33228: Dual chamber pacemaker generator replacement
  • 33229: Multiple lead pacemaker generator replacement
  • 33233: Removal of permanent pacemaker pulse generator only

Why 33228 is the Correct Code

The scenario describes a physician changing an old battery to a new one on a patient's dual chamber permanent pacemaker. This procedure specifically involves:

  1. Accessing the existing pacemaker pocket
  2. Disconnecting the old generator from the existing leads
  3. Connecting a new generator to the existing leads
  4. Testing the system
  5. Closing the incision

The dual chamber nature of the pacemaker (having both atrial and ventricular leads) is the key determinant for code selection, making 33228 the appropriate choice.

Why Other Codes Are Incorrect

  • 33212: This code is for the initial insertion of a single chamber pacemaker, not a battery replacement
  • 33213: This code is for the initial insertion of a dual chamber pacemaker, not a battery replacement
  • 33229: This code is for replacement of a multiple lead (more than 2) pacemaker generator
  • 33233-51: This code combination is incorrect as 33233 only covers removal of a generator without replacement

Clinical Considerations During Battery Replacement

Battery replacement procedures require careful attention to:

  1. Pacemaker dependency assessment: Determine if the patient is pacemaker-dependent before the procedure to ensure appropriate precautions are taken

  2. Continuous monitoring: Maintain ECG monitoring throughout the procedure

  3. Device programming: After replacement, verify proper functioning of the pacemaker system including:

    • Capture thresholds
    • Sensing parameters
    • Lead impedance values
  4. Post-procedure evaluation: Monitor for complications such as pocket hematoma, lead dislodgement, or infection

Procedural Approach

The battery replacement procedure typically takes 30-60 minutes and involves:

  • Local anesthesia (typically lidocaine 1-2%)
  • Sterile preparation of the surgical site
  • Incision over the existing pocket
  • Careful removal of the old generator while preserving lead connections
  • Connection of the existing leads to the new generator
  • Testing of the system before pocket closure
  • Closure of the incision

This procedure carries lower risk than initial implantation but still requires careful technique to avoid complications.

AI: I've provided the correct CPT code (33228) for replacing a dual chamber pacemaker battery/generator, along with an explanation of why this is the correct code and why the other options are incorrect. I've also included relevant clinical considerations during the procedure.

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.