What is the relationship between secretion suction frequency and endotracheal tube (ETT) capping trials?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: March 22, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

From the Guidelines

Endotracheal suctioning should be performed only when clinically indicated, rather than on a fixed schedule, to minimize complications and reduce the risk of ventilator-associated pneumonia (VAP) 1. When considering the relationship between secretion suction frequency and endotracheal tube (ETT) capping trials, it is essential to prioritize evidence-based protocols that balance effective airway management with minimizing complications.

  • The use of closed endotracheal suction systems that are changed for each new patient and as clinically indicated is recommended, as it has been shown to have no effect on the incidence of VAP, while also considering cost reductions 1.
  • Subglottic secretion drainage has been associated with decreased incidence of VAP, especially early-onset VAP, and should be considered by clinicians 1. Key factors to consider when determining secretion suction frequency include:
  • The presence of audible or visible secretions
  • Changes in oxygen saturation
  • Ventilator graphics showing increased airway resistance For capping trials in tracheostomy patients, a structured protocol should be implemented, starting with short trials (5-10 minutes) and gradually increasing to 30-60 minutes as tolerated, while monitoring oxygen saturation, respiratory rate, and work of breathing 1. It is crucial to individualize both suction frequency and capping trial duration based on patient-specific factors, such as secretion volume, viscosity, and underlying respiratory condition, to ensure optimal outcomes and minimize complications.
  • Patient monitoring during capping trials should include oxygen saturation, respiratory rate, and work of breathing to assess readiness for decannulation and prevent potential complications. By prioritizing evidence-based protocols and individualizing care, clinicians can minimize the risk of VAP and other complications associated with endotracheal suctioning and capping trials.

From the Research

Relationship Between Secretion Suction Frequency and Endotracheal Tube (ETT) Capping Trials

  • The relationship between secretion suction frequency and ETT capping trials is not directly addressed in the provided studies 2, 3, 4, 5, 6.
  • However, the studies discuss the importance of suctioning frequency in preventing ventilator-associated pneumonia and the recommended frequency for oropharyngeal suctioning 2.
  • A study suggests that a minimum frequency of oropharyngeal suctioning every 4 hours is recommended, but more frequent suctioning may be needed in a subset of patients 2.
  • Another study recommends that endotracheal suctioning should be performed only when secretions are present, and not routinely 3.
  • The effectiveness of open and closed suctioning systems is compared in a study, which found that they are similar in terms of haemodynamic alterations, amounts of secretion, and frequency of suctioning 4.
  • A systematic review highlights the importance of artificial airway suctioning in ensuring airway patency and the need for healthcare professionals to be aware of the safest and most efficient ways to perform suctioning 5.
  • A survey of nurses and respiratory therapists found that they often practice normal saline instillation despite evidence-based practice guidelines suggesting that this therapy may be detrimental to patients 6.

Suctioning Frequency and ETT Capping Trials

  • There is no direct evidence in the provided studies to support a specific relationship between secretion suction frequency and ETT capping trials.
  • However, the studies suggest that suctioning frequency is an important aspect of ETT management, and that healthcare professionals should be aware of the recommended frequencies and guidelines for suctioning 2, 3, 4, 5, 6.

References

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Research

Oropharyngeal secretion volume in intubated patients: the importance of oral suctioning.

American journal of critical care : an official publication, American Association of Critical-Care Nurses, 2011

Research

Endotracheal suctioning practices of nurses and respiratory therapists: How well do they align with clinical practice guidelines?

Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR, 2015

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.