What is the normal peak systolic velocity (PSV) for a young man with normal erectile function?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: October 19, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Normal Peak Systolic Velocity in Young Men with Normal Erectile Function

The normal peak systolic velocity (PSV) for a young man with normal erectile function is ≥35 cm/sec, which indicates normal arterial supply to the penis. 1

Understanding Peak Systolic Velocity Measurements

  • PSV is measured in the cavernosal arteries using duplex sonography after intracavernosal injection of vasodilatory agents (such as papaverine or prostaglandin E1) 1
  • PSV values ≥35 cm/sec are strongly associated with normal arterial function and normal erectile function 1, 2
  • PSV values between 25-34 cm/sec may indicate mild to moderate arterial insufficiency 1
  • PSV values <25 cm/sec typically indicate severe arterial disease 1

Clinical Significance of PSV Measurements

  • PSV measurements provide objective assessment of penile arterial inflow, which is crucial for normal erectile function 2
  • PSV ≥35 cm/sec has high specificity (93.5%) for normal arterial function 3
  • Only about 3.7% of men with PSV ≥35 cm/sec have underlying ischemic heart disease, compared to 41.9% of men with PSV <35 cm/sec 2
  • PSV measurements can serve as a screening tool for potential cardiovascular disease in men presenting with erectile dysfunction 2, 4

Important Considerations and Potential Pitfalls

  • Young men (under 30 years) may show falsely low PSV values during initial testing due to anxiety and increased sympathetic tone 5
  • Repeat testing is recommended for young patients with unexpectedly low PSV values before making definitive diagnoses 5
  • Environmental factors and psychological state during testing can significantly influence PSV measurements, particularly in younger patients 5
  • The sensitivity of PSV <35 cm/sec for detecting ischemic heart disease is approximately 92.9%, with a specificity of 59.1% 2

Technical Aspects of Measurement

  • Proper technique is essential for accurate PSV measurement, including appropriate dosing of vasodilatory agents and timing of measurements 1, 3
  • Some studies have explored measuring PSV in the flaccid state (basal PSV), with values >12.5 cm/sec often predictive of normal dynamic PSV (≥30 cm/sec) when combined with acceleration >1 m/sec² 3
  • Standard protocol typically involves measurement 5-20 minutes after intracavernosal injection of vasodilatory agents 1, 4

In clinical practice, PSV values should be interpreted in the context of the patient's age, cardiovascular risk factors, and overall health status, as these measurements can provide insights beyond just erectile function assessment 2, 4.

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.