What changes are seen in the pulse oximeter (oxygen saturation monitor) waveform when a patient temporarily holds their breath?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: December 21, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Pulse Oximeter Waveform Changes During Breath-Holding

During breath-holding, the pulse oximeter waveform initially remains unchanged, but after approximately 15-16 seconds, you will observe a characteristic downward deflection in the oxygen saturation reading that corresponds to the circulation time from the lungs to the finger probe, followed by a progressive decline in SpO2 if breath-holding continues.

Initial Phase (0-15 seconds)

  • The plethysmographic waveform amplitude and SpO2 reading remain stable during the first 15-16 seconds of breath-holding because oxygenated blood that was in the lungs at the start of the breath-hold is still circulating to the peripheral probe site 1.

  • The heart rate displayed on the pulse oximeter continues to be detected accurately through arterial pulsations, as pulse oximetry reliably monitors heart rate by detecting arterial pulsations with each heartbeat 2.

  • This initial plateau period represents the circulation time from alveoli to the finger probe location, which averages 15-16 seconds in healthy individuals at sea level 1.

Characteristic Downward Peak (15-16 seconds)

  • A distinct down-pointed peak in SpO2 appears at approximately 16 seconds, marking the arrival of deoxygenated blood from the lungs to the finger probe 1.

  • This phenomenon occurs even when breathing high concentrations of oxygen before breath-holding, though the breath-hold time is prolonged under these circumstances 1.

  • The timing of this peak provides a non-invasive measurement of circulation time and is observable in both normal individuals and those with chronic hypoxia 1.

Progressive Desaturation Phase (>16 seconds)

  • After the initial circulation time delay, SpO2 begins to fall progressively as deoxygenated blood continues to circulate from the non-ventilated alveoli 3, 4.

  • The rate of fall in oxygen saturation during breath-holding is similar whether respiratory efforts are present or absent, with the decline following a predictable pattern (approximately 5.5-6.8% per unit time, depending on initial saturation) 3.

  • In healthy divers performing maximal breath-holds averaging 69 seconds, mean SpO2 can drop to approximately 73% by the end of the breath-hold 4.

  • For routine shorter breath-holds (15-44 seconds), SpO2 may show minimal or no significant reduction below baseline values of 98% 4.

Critical Clinical Distinction

  • Pulse oximetry cannot detect the hypoventilation or CO2 accumulation occurring during breath-holding because it only measures oxygen saturation, not ventilation adequacy 5, 2.

  • The waveform provides no information about rising PaCO2 levels, which increase immediately when breath-holding begins, while SpO2 remains falsely reassuring during the initial circulation time period 5, 6.

  • This represents a fundamental limitation: pulse oximetry is a late indicator of respiratory compromise and does not detect early decreases in adequacy of ventilation or the onset of hypercarbia 2.

Waveform Quality Indicators

  • The plethysmographic waveform amplitude should remain consistent throughout breath-holding if perfusion is adequate, as the pulse oximeter continues to detect arterial pulsations 2.

  • Loss of waveform quality or amplitude during breath-holding suggests poor perfusion from factors such as vasoconstriction, hypothermia, or reduced cardiac output rather than the breath-holding itself 2, 6.

References

Research

Non-invasive measurement of circulation time using pulse oximetry during breath holding in chronic hypoxia.

Journal of physiology and pharmacology : an official journal of the Polish Physiological Society, 2005

Guideline

Pulse Oximeter Waveform: Reliable Clinical Information

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Research

Continuous pulse oximetry in the breath-hold diving women of Korea and Japan.

Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc, 1993

Guideline

Elevated End-Tidal CO2 in Hypoventilation

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Guideline

Causes of Low Pulse Oximetry with Normal Respiratory Function

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.