Can a 1cm difference in testicle length between two scrotal ultrasounds (ultrasound scans) performed 4 weeks apart be due to a different technician performing the scan?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: December 28, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Testicular Measurement Variability Between Ultrasounds

A 1cm difference in testicular length between two scrotal ultrasounds performed 4 weeks apart is most likely due to inter-operator measurement variability and technical factors rather than true biological change. 1, 2

Understanding Measurement Variability

Inter-operator variability is a well-recognized source of measurement discrepancy in testicular ultrasound. The difference you observed (4cm vs 3.1cm) represents approximately a 22% variation, which falls within the range of expected measurement error between different sonographers. 2

Technical Factors Contributing to Measurement Differences

  • Caliper placement errors are the most common source of measurement discrepancy, as incorrect positioning during ultrasound can lead to severely inconsistent volume calculations and measurements. 1

  • Different measurement techniques between operators can produce significant variations—studies show that external measurements with calipers overestimate testicular length by an average of 5.7mm compared to ultrasound, and even ultrasound measurements vary based on probe positioning and angle. 3

  • Built-in software differences between ultrasound systems can produce discordant values, with some systems calculating volumes that differ by up to 26.76% when using different formulas. 2

  • Lack of standardized measurement protocols means that unless the same reporter uses a standardized technique, measurements should ideally be repeated on previous scans to minimize inter-scan variability. 4

Clinical Significance of Your Measurements

Both measurements (4cm and 3.1cm) correspond to testicular volumes in the normal range (approximately 15-18ml for 4cm and 10-12ml for 3.1cm), though the smaller measurement approaches the lower threshold of normal. 1

What This Means for You

  • A 4cm testicular length corresponds to approximately 15-18ml volume, which is within normal adult range and associated with normal spermatogenesis. 1

  • A 3.1cm measurement would correspond to approximately 10-12ml, which is at or just below the 12ml threshold that defines potential testicular atrophy. 1, 5

  • Size discrepancy greater than 2ml or 20% between measurements warrants repeat ultrasound with explicit attention to proper measurement technique to confirm true testicular volume. 1, 6

Recommended Next Steps

Request a repeat scrotal ultrasound with explicit instructions for standardized measurement technique to resolve the discrepancy and establish an accurate baseline. 1

Specific Technical Requirements for Repeat Scan

  • High-frequency probes (>10 MHz) should be used to maximize resolution and accurate caliper placement. 1

  • Measurements should include three perpendicular dimensions (length, width, height) on axial slices, preferably on T2-weighted sequences or their ultrasound equivalent. 4, 7

  • Volume should be calculated using the Lambert formula: Length × Width × Height × 0.71, as this is the standard recommended by updated guidelines. 2, 8

  • The same sonographer should perform serial measurements when possible, or measurements should be remeasured on previous scans by the current operator to minimize inter-scan variability. 4

Important Clinical Caveats

True biological change in testicular size over 4 weeks is extremely unlikely in adults unless there is acute pathology such as torsion, trauma, infection, or rapidly growing tumor—none of which would present as an isolated size decrease without symptoms. 4

  • If repeat ultrasound confirms volume <12ml, hormonal evaluation (FSH, LH, testosterone) should be obtained, as volumes below this threshold are associated with impaired spermatogenesis and higher risk of intratubular germ cell neoplasia. 1, 5

  • Normal fertility and absence of symptoms make true testicular atrophy unlikely, further supporting measurement error as the explanation. 1

  • Avoid unnecessary anxiety about the discrepancy until proper repeat measurement with standardized technique confirms or refutes the smaller measurement. 1, 2

References

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.