What is the anion gap and its significance in evaluating a patient's acid-base balance?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: January 14, 2026View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Understanding the Anion Gap

Definition and Calculation

The anion gap is a calculated value that represents the difference between measured cations and anions in serum, serving as a critical tool for identifying and categorizing metabolic acidosis. 1

The anion gap is calculated using the formula: Na+ + K+ - Cl- - HCO3- 2, though some laboratories use the simplified formula without potassium: [Na+] - ([Cl-] + [HCO3-]) 3. The calculation essentially estimates the difference between unmeasured anions (primarily albumin, phosphate, sulfate, and organic acids) and unmeasured cations (calcium, magnesium, immunoglobulins) 1.

Normal Reference Range

  • The modern reference range is 3-11 mmol/L when using ion-selective electrode methodology, which is significantly lower than the historically cited range of 8-16 mmol/L 4
  • When potassium is included in the calculation (Na+ + K+ - Cl- - HCO3-), the normal range is approximately 8-12 mmol/L 5
  • Clinicians must be aware that many textbooks still reference the outdated range of 8-16 mmol/L, which can lead to misinterpretation 4

Clinical Significance in Acid-Base Evaluation

Primary Diagnostic Function

The anion gap divides metabolic acidoses into two fundamental categories: high anion gap metabolic acidosis (HAGMA) and normal anion gap (hyperchloremic) metabolic acidosis, thereby narrowing the differential diagnosis 1.

  • High anion gap acidosis occurs when non-chloride organic acids accumulate in the blood, displacing bicarbonate without a corresponding rise in chloride 3
  • Normal anion gap acidosis occurs when bicarbonate is lost and replaced by chloride, maintaining the anion gap 6

Common Causes of Elevated Anion Gap

The differential diagnosis includes (mnemonic: GOLDMARK):

  • Glycols (ethylene glycol, propylene glycol) - particularly critical as anion gap >27 mmol/L warrants immediate hemodialysis 2
  • Oxoproline (acetaminophen toxicity)
  • L-lactate (lactic acidosis from shock, sepsis, tissue hypoxia) 2
  • D-lactate
  • Methanol
  • Aspirin (salicylates)
  • Renal failure (uremic acidosis) 2
  • Ketoacidosis (diabetic, alcoholic, starvation) 2

Advanced Interpretation: Delta Gap Analysis

The delta gap (Δ AG/Δ HCO3-) reveals occult concurrent acid-base disorders that would otherwise be missed 6.

Calculation Method

  • Δ anion gap = observed anion gap - normal anion gap
  • Δ HCO3- = normal HCO3- - observed HCO3-
  • Delta ratio = Δ AG / Δ HCO3- 3

Interpretation Algorithm

  • Ratio of 1:1 indicates simple high anion gap acidosis - the expected pattern where each mEq/L rise in anion gap corresponds to a 1 mEq/L fall in bicarbonate 6
  • Ratio <1 (or <0.8) suggests combined high anion gap acidosis PLUS normal anion gap acidosis - bicarbonate is falling more than the anion gap is rising, indicating additional bicarbonate loss (e.g., diarrhea with lactic acidosis) 6
  • Ratio >2 suggests combined high anion gap acidosis PLUS metabolic alkalosis - bicarbonate is not falling as much as expected, indicating a concurrent process raising bicarbonate (e.g., vomiting with ketoacidosis) 6

Clinical Nuances

  • The delta ratio varies by the type of retained anion: lactic acidosis typically produces a ratio closer to 1:1, while ketoacidosis often produces ratios >1.6 due to renal excretion of ketone salts 7
  • This variation occurs because ketone bodies can be excreted as sodium or potassium salts, effectively removing acid without lowering bicarbonate proportionally 7

Critical Adjustments and Pitfalls

Hypoalbuminemia Correction

Severe hypoalbuminemia significantly lowers the calculated anion gap because albumin is the major unmeasured anion, potentially masking a true high anion gap acidosis 8.

  • For every 1 g/dL decrease in albumin below 4 g/dL, add approximately 2.5 mEq/L to the calculated anion gap 1
  • A patient with albumin of 2 g/dL and an anion gap of 10 mmol/L actually has a corrected anion gap of 15 mmol/L (10 + [2 × 2.5]) 1

Low Anion Gap: Red Flags

An anion gap <3 mmol/L or negative values should prompt investigation for specific clinical conditions or laboratory errors 4:

  • Severe hypoalbuminemia (most common cause) 8
  • Hyperglobulinemia (multiple myeloma, particularly IgG subtype) 4
  • Lithium or barium intoxication (increases unmeasured cations) 8
  • Laboratory measurement artifacts 4

A baseline low anion gap can dangerously mask concurrent high anion gap metabolic acidosis, requiring arterial blood gas analysis to assess true acid-base status 8.

Quality Control Applications

  • Anion gap >24 mmol/L is rare and should prompt verification of electrolyte measurements or investigation for severe metabolic acidosis 4
  • Anion gap <2 mmol/L is extremely rare and warrants checking for hypoalbuminemia, hyperglobulinemia, or laboratory error 4
  • The anion gap serves as an internal quality control check: significant deviations suggest either true pathology or measurement error 4

Integration with Osmolal Gap

When combined with osmolal gap calculations, the anion gap helps identify toxic alcohol ingestions (methanol, ethylene glycol) that produce both an elevated osmolal gap early and an elevated anion gap as toxic metabolites accumulate 1.

  • For ethylene glycol poisoning with anion gap >27 mmol/L, immediate hemodialysis is strongly recommended 2
  • For anion gap 23-27 mmol/L with suspected ethylene glycol exposure, hemodialysis should be considered 2
  • Mortality increases significantly (20.4%) when anion gap exceeds 28 mmol/L in ethylene glycol poisoning 2

Limitations in Clinical Practice

  • There is substantial individual variation in baseline anion gap (often 8-10 mEq/L range), meaning mild elevations may be missed when using population-based reference ranges 7
  • The anion gap has poor predictive value when used indiscriminately without clinical context 2
  • Certain medications and conditions can falsely alter the anion gap (e.g., hyperphosphatemia increases unmeasured anions) 2
  • Elevated glycolate concentration can falsely elevate plasma lactate on some analyzers, potentially confusing the clinical picture 2

References

Research

Approach to Patients With High Anion Gap Metabolic Acidosis: Core Curriculum 2021.

American journal of kidney diseases : the official journal of the National Kidney Foundation, 2021

Guideline

Initial Management of Elevated Anion Gap

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2026

Research

Anion-gap metabolic acidemia: case-based analyses.

European journal of clinical nutrition, 2020

Research

Update on value of the anion gap in clinical diagnosis and laboratory evaluation.

Clinica chimica acta; international journal of clinical chemistry, 2001

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Research

Clinical utility of anion gap in deciphering acid-base disorders.

International journal of clinical practice, 2009

Guideline

Clinical Significance of a Low Anion Gap

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.