What does an Inferior Vena Cava (IVC) maximum diameter of less than 2.1 cm that collapses more than 50% with or without a sniff indicate regarding right atrial pressure?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: May 15, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

From the Guidelines

An IVC maximum diameter <2.1 cm that collapses >50% with or without a sniff is indeed inconsistent with intravascular volume overload and suggests normal right atrial pressure, typically 0-5 mmHg, as supported by the 2015 ESC/ERS guidelines for the diagnosis and treatment of pulmonary hypertension 1.

Key Points

  • The IVC diameter and collapsibility serve as useful bedside ultrasonographic markers for assessing a patient's volume status.
  • During inspiration, negative intrathoracic pressure normally causes the IVC to collapse; this collapse is exaggerated when right atrial pressures are low.
  • Conversely, in volume overload states, the IVC becomes dilated and loses this collapsibility.
  • This assessment is particularly valuable in clinical scenarios such as managing heart failure, guiding fluid resuscitation, or evaluating patients with hypotension.

Clinical Application

  • The technique requires placing the ultrasound probe in the subxiphoid region to visualize the IVC as it enters the right atrium, then measuring its diameter during normal respiration and during a sniff or deep inspiration to calculate the percentage of collapse.
  • According to the guidelines, an IVC diameter < 2.1 cm that collapses > 50% with a sniff suggests a normal RA pressure of 3 mmHg (range, 0–5 mmHg) 1.
  • In scenarios where the IVC diameter and collapse do not fit this paradigm, an intermediate value of 8 mmHg (range, 5–10 mmHg) may be used, or other indices of RA pressure should be integrated to downgrade or upgrade to the normal or high values of RA pressure.

From the Research

IVC Diameter and Collapsibility

  • The IVC maximum diameter <2.1 cm, that collapses >50% with or without a sniff is inconsistent with intravascular volume overload and suggests normal right atrial pressure (0-5 mmHg) 2
  • IVC collapsibility index (IVC CI) < 20% with no sniff suggests increased right atrial pressure and is inconsistent with overt hypovolemia in spontaneously breathing or ventilated patients 2

Factors Influencing IVC Diameter and Collapsibility

  • The presence of significant tricuspid regurgitation, a larger body surface area, and younger age are associated with the IVC maximum diameter, independently of right atrial pressure 3
  • IVC collapsibility index (IVCCI) is influenced only by right atrial pressure 3

Clinical Applications of IVC Ultrasonography

  • Preoperative ultrasound IVC measurements can predict hypotension after induction of anesthesia 4
  • IVC ultrasonographic criteria for hemodynamic congestion appear inconsistent, and a sequential or simultaneous combination of clinical scores of congestion, IVC ultrasonographic indices, and circulating levels of natriuretic peptides may be warranted 5

Measurement of IVC Diameter

  • The anterioposterior projective diameter (PD) is significantly larger than the circumference-based calculated diameter (CD) 6
  • Measurement of CD may be better to assess maximum IVC diameter compared with PD for the purpose of IVC filter placement 6

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.