Can a chest x-ray be used to verify the position of an Impella (Intra-Aortic Balloon Pump) device?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: June 1, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

From the Research

Yes, a chest x-ray can be used to verify the position of an Impella device, though it's essential to note that an Impella is not the same as an Intra-Aortic Balloon Pump (IABP) - they are different cardiac support devices. For Impella position verification, chest x-rays provide a quick, readily available method to assess the general placement of the device. The radiopaque markers on the Impella catheter can be visualized on x-ray, allowing clinicians to confirm that the inlet area is properly positioned below the aortic valve and the outlet area is above it. However, chest x-rays have limitations in providing precise positioning details compared to other imaging modalities. While x-rays can detect gross malposition, echocardiography (particularly transesophageal echocardiography) is considered the gold standard for accurate Impella positioning assessment as it provides real-time visualization of the device in relation to cardiac structures, as discussed in 1. Fluoroscopy during initial placement and angiography can also provide more detailed information about positioning. The reason chest x-rays remain useful is their accessibility, speed, and ability to simultaneously evaluate for complications such as pneumothorax or device migration, as highlighted in a recent review on chest X-ray interpretation for detecting devices and device-related complications 2.

Some key points to consider when using chest x-rays for Impella position verification include:

  • The importance of radiopaque markers on the Impella catheter for visualization on x-ray
  • The limitations of chest x-rays in providing precise positioning details
  • The role of echocardiography as the gold standard for accurate Impella positioning assessment
  • The usefulness of fluoroscopy and angiography for more detailed information about positioning
  • The ability of chest x-rays to evaluate for complications such as pneumothorax or device migration, as noted in 2.

It's also worth noting that while other studies discuss the role of echocardiography in left ventricular assist device implantation and evaluation 3, 4, 5, the most recent and relevant evidence for chest x-ray use in Impella position verification is found in 2.

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.