Bone Scan for Hardware Loosening After Hemiarthroplasty
For suspected hardware loosening after hemiarthroplasty, a Tc-99m 3-phase bone scan with SPECT or SPECT/CT is the recommended nuclear medicine study, though it has high sensitivity but low specificity and cannot reliably differentiate loosening from infection. 1
Understanding the Imaging Approach
Why Bone Scans Are Used
Tc-99m bone scintigraphy is highly sensitive for detecting hardware loosening when radiographs are normal or equivocal. However, the critical limitation is poor specificity—increased uptake can represent:
- Normal postoperative bone remodeling (up to 1-2 years post-surgery)
- Aseptic loosening
- Periprosthetic infection
- Periprosthetic fracture 1
Single-Phase vs. 3-Phase Bone Scan
Single-phase bone scan (Tc-99m MDP):
- Sensitive for loosening detection
- Low specificity
- Cannot differentiate between loosening, infection, or normal remodeling 1
3-phase bone scan with SPECT or SPECT/CT (preferred):
- Provides better anatomic localization of active bone remodeling 1
- Still nonspecific but offers more information
- Positive uptake on delayed images (but not blood-pool phase) suggests loosening rather than infection 2, 3
- SPECT/CT improves diagnostic accuracy by combining metabolic and anatomic data 4
Critical Timing Considerations
The specificity of bone scans increases significantly in older prostheses (>2 years post-surgery) once normal postoperative remodeling has stabilized. 1
- Normal postoperative uptake persists up to 1-2 years after surgery
- Aseptic loosening tends to show progressive uptake over time on serial scans
- Normal postoperative changes decrease over time 1
When Bone Scans Are Most Useful
High negative predictive value: A normal bone scan effectively excludes loosening or infection 2
Caveat: False negatives can occur if loosening is at the cement-prosthetic interface without new bone formation 2
Alternative and Complementary Imaging
CT with Metal Artifact Reduction
CT is actually superior to bone scans for evaluating hardware loosening when infection has been excluded:
- Better demonstrates periprosthetic lucency, osteolysis, hardware malposition, and component migration 1
- Evaluates bone stock and component alignment
- Modern metal reduction software has dramatically improved image quality 1
- Does not require IV or intra-articular contrast 1
If Infection Cannot Be Excluded
When bone scan is positive and infection remains a concern, proceed to:
- In-111 WBC scan combined with Tc-99m sulfur colloid bone marrow imaging to differentiate infection from aseptic loosening 1
- Spatially congruent WBC and marrow activity = aseptic loosening (reactive marrow)
- WBC accumulation with marrow photopenia = infection 1
Practical Algorithm
- Start with radiographs (always first-line)
- If radiographs normal/equivocal and loosening suspected:
- If prosthesis >2 years old: 3-phase bone scan with SPECT/CT has better specificity
- If prosthesis <2 years old: Consider CT with metal artifact reduction first (avoids false positives from normal remodeling)
- If bone scan positive: Cannot differentiate loosening from infection—proceed to WBC/sulfur colloid imaging if infection not excluded clinically
- If infection excluded: CT with metal artifact reduction provides superior anatomic detail for surgical planning 1
Common Pitfalls
- Don't order bone scans in early postoperative period (<1 year) without understanding that positive results may reflect normal healing
- Don't rely on bone scans alone to differentiate loosening from infection—they cannot do this reliably 1, 3
- Don't forget serial imaging: Progressive uptake over time favors loosening; decreasing uptake favors normal postoperative change 1
- Recent evidence suggests SPECT/CT without arthrography is sufficient—adding arthrography provides minimal benefit and adds infection risk 5