What are the recent advances in cardiac output (CO) monitoring techniques?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: November 23, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Recent Advances in Cardiac Output Monitoring

The field of cardiac output monitoring has evolved significantly with the integration of wearable biosensor technologies, machine learning algorithms for real-time interpretation, and novel non-invasive techniques including ballistocardiography, though these advances must be balanced against concerns about accuracy, clinical actionability, and the continued role of traditional invasive monitoring in specific high-risk populations.

Wearable and Non-Invasive Technologies

The most significant recent advance is the development of wearable sensor technologies that can continuously measure cardiac output along with multiple other biosignals including blood pressure, heart rhythm, and respiratory rate 1. These devices represent a paradigm shift from intermittent to continuous monitoring:

  • Ballistocardiography sensors are being developed to measure myocardial contractility and cardiac output non-invasively, offering potential for ambulatory monitoring outside traditional clinical settings 1.

  • Multi-modal chest patches can simultaneously monitor heart rate, rhythm, respiration rate, and skin temperature, providing integrated hemodynamic assessment 1.

  • These wearable technologies enable continuous biosignal acquisition that can create personalized physiological "portraits" for individual patients, particularly valuable for detecting early signs of heart failure decompensation 1.

Critical Limitation to Consider

The use of these novel biosignals raises significant concerns regarding accuracy and actionability within clinical guidelines, along with medical, legal, and ethical issues that remain unresolved 1. The devices cannot provide real-time alerts for life-threatening conditions in the same way implantable devices can 2.

Machine Learning Integration

Machine learning algorithms now enable near-real-time, specialist-level interpretation of hemodynamic data from monitoring devices, representing a major advance in how cardiac output data is analyzed 1:

  • These algorithms can facilitate rapid evaluation of the hemodynamic consequences of heart failure or arrhythmias 1.

  • However, machine learning interpretation is limited by noise in biosensor data and training datasets that may not represent real-world clinical settings 1.

Implantable Device Advances

Cardiac implantable electronic devices (CIEDs) remain the gold standard for continuous cardiac monitoring, with over three million patients in the USA having these devices 1:

  • CIEDs can now provide indices of heart rate variability and pulmonary impedance to track heart failure and alert for possible decompensation 1.

  • Diminished heart rate variability (<100 ms) indicates increased sympathetic activity and is associated with increased risk of death, worsening heart failure, and malignant ventricular arrhythmias 1.

  • Pulmonary artery pressure monitoring through implanted sensors represents a promising biosignal for heart failure detection 1.

Traditional Invasive Monitoring: Still Relevant

Despite technological advances, pulmonary artery catheter (PAC) thermodilution remains the gold standard for cardiac output measurement, particularly in patients with cardiac pathology and when used by experienced operators 3:

  • PAC has made a comeback in clinical practice, especially in cardiac intensive care units 3.

  • Invasive techniques are more accurate than non-invasive alternatives, though their invasiveness carries higher complication risks 3.

  • PAC should still be recommended when monitoring of pulmonary artery pressures is desirable in specific clinical situations 4.

Critical Care Echocardiography

Critical care echocardiography (CCE) offers a valid alternative to thermodilution that provides not only cardiac output but also differential diagnosis 3:

  • CCE is suitable for all ICUs and provides fast, non-invasive cardiac output measurement 5.

  • The main hindrances to widespread adoption are lack of proper training and equipment availability 3.

  • Transesophageal echocardiography and Doppler measurements remain limited by high operator dependency 4.

Minimally Invasive Techniques

Several minimally invasive options have emerged as alternatives to PAC 4, 5, 6:

  • Pulse wave analysis has been validated as a reliable alternative to PAC in different clinical settings, allowing continuous minimally invasive cardiac output measurement 4, 5.

  • Transpulmonary thermodilution and lithium dilution techniques provide less invasive options 5.

  • Bioreactance and Doppler techniques currently provide valid, fast, and non-invasive cardiac output measurement 5.

Important Caveat

It is how the monitor is used (the protocol or therapy associated with its use), not the monitor itself, that determines patient outcomes 7. These devices must be used within the context of hemodynamic optimization protocols to positively influence outcomes 6.

Data Security and Ethical Challenges

The use of data from cardiovascular monitoring devices is associated with numerous challenges including data security, accessibility, ownership, and regulatory concerns 1. These issues must be addressed before integrated and scalable cardiovascular monitoring tools can be fully developed 1.

Clinical Algorithm for Device Selection

For cardiac surgery ICU patients or those with complex cardiac pathology: Use PAC thermodilution with experienced operators 3.

For general ICU patients requiring continuous monitoring: Consider pulse wave analysis or critical care echocardiography if trained personnel available 3, 4.

For ambulatory heart failure monitoring: Wearable biosensor technologies with machine learning interpretation, recognizing accuracy limitations 1.

For rhythm monitoring only: Chest patch devices like Zio Patch for extended recording, though these cannot provide real-time alerts 2.

References

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Guideline

Cardiac Monitoring with the Zio Patch

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Research

Cardiac output monitoring - invasive and noninvasive.

Current opinion in critical care, 2022

Research

What technique should I use to measure cardiac output?

Current opinion in critical care, 2007

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.