What are the most common causes of a failed spinal anesthesia with good cerebrospinal fluid (CSF) flow?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: December 2, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Failed Spinal Anesthesia with Good CSF Flow

The most common causes of failed spinal anesthesia despite good CSF flow are inadequate drug spread through CSF (due to variable lumbosacral CSF volumes, patient positioning, or baricity issues), drug preparation errors, and insufficient dosing for the patient's anatomical characteristics. 1

Primary Mechanisms of Failure

Inadequate Drug Distribution in CSF

  • Lumbosacral CSF volume is the primary determinant of sensory block extent and duration, with volumes ranging from 42.7 to 81.1 ml among individuals, directly correlating with peak sensory block height and duration of anesthesia 2
  • Patients with larger CSF volumes require proportionally more local anesthetic to achieve adequate spread, explaining why standard doses fail in some patients despite successful dural puncture 2
  • Poor mixing or inadequate spread of local anesthetic within the subarachnoid space can occur even with correct needle placement and free-flowing CSF 1

Drug Preparation and Administration Errors

  • Errors in drug preparation, dilution, or selection of the wrong concentration are significant causes of failure that occur after successful lumbar puncture 1
  • Inadvertent injection of the wrong solution (saline instead of local anesthetic, or incorrect drug entirely) can occur despite good CSF flow 1
  • Insufficient volume or dose of local anesthetic for the patient's body habitus and CSF volume 1

Technical Issues Despite CSF Return

  • Catheter or needle migration out of the subarachnoid space during or after injection, even when initial CSF flow was good 3
  • Subdural injection can occur with initial CSF return, but the drug spreads inadequately in the subdural space rather than the subarachnoid space 1
  • Partial subarachnoid injection where only a portion of the dose enters the CSF 1

Patient-Related Factors

Anatomical Variability

  • Individual variation in lumbosacral CSF volume (ranging nearly 2-fold between patients) is the most important identified factor contributing to variability in spinal anesthesia spread 2
  • Spinal canal anatomy, including presence of adhesions, septations, or previous spinal surgery, can prevent adequate drug distribution 1
  • Obesity and increased intra-abdominal pressure can affect CSF dynamics and drug spread 1

Positioning and Baricity Issues

  • Patient positioning after injection significantly affects hyperbaric or hypobaric solution spread; inadequate positioning can result in unilateral or patchy blocks 1
  • Failure to maintain appropriate position long enough for drug fixation to neural tissue 1

Drug-Related Mechanisms

Pharmacological Failure

  • Failure of drug action on nervous tissue can occur despite adequate spread, though this is rare 1
  • Tachyphylaxis in patients who have received recent neuraxial anesthesia 1
  • Inadequate time allowed for onset; different local anesthetics have varying onset times 1

Clinical Management Approach

Immediate Assessment

  • Verify the correct drug and dose were administered by checking the syringe and vial 1
  • Assess the pattern of failure: complete absence of block, inadequate height, unilateral block, or patchy distribution 1
  • Consider whether sufficient time has elapsed for the specific local anesthetic used 1

Management Options

  • Repeating the spinal injection at a different interspace may be considered if complete failure occurred and adequate time has passed 1
  • Supplementation with local infiltration by the surgeon for minor inadequacies 1
  • Systemic sedation and analgesia to supplement an inadequate but partially effective block 1
  • Conversion to general anesthesia for significant failures 1

Prevention Strategies

  • Use standardized techniques and close attention to detail at every step of the procedure 1
  • Consider patient-specific factors including body habitus, previous spinal surgery, and estimated CSF volume when selecting dose 2
  • Ensure adequate time for block onset before declaring failure 1
  • Maintain meticulous documentation of technique, drugs used, and patient positioning 1

Important Caveats

  • Good CSF flow confirms dural puncture but does not guarantee adequate drug distribution or effect 1
  • The needle-through-needle combined spinal-epidural technique provides reassurance of correct midline placement when CSF flows freely, making inadequate spread less likely 3
  • In obstetric patients, intrathecal catheter failure rates of 5.7% have been reported despite confirmed CSF flow, often due to inadequate drug spread or catheter migration 3
  • Always maintain full documentation and provide patient explanation when failure occurs 1

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.