What are the chances of a failed epidural (peridural anesthesia)?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: December 30, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Epidural Failure Rates

Epidural anesthesia fails to provide adequate analgesia in approximately 3.5-32% of cases, with most contemporary studies reporting failure rates between 5-21%. 1

Baseline Failure Rates by Clinical Context

Labor Epidurals

  • Overall failure rate: 3.5-32% depending on the study and definition of failure 1
  • Inadequate pain relief requiring intervention: 21% in a large prospective observational study 2
  • Complete catheter dislodgement at skin: 0.53% 1

Conversion to Cesarean Anesthesia

  • Failed conversion from labor epidural to cesarean anesthesia occurs in approximately 3.5-7.1% of cases when the epidural was functioning adequately during labor 1
  • This rate increases substantially with certain risk factors (see below) 3

Intrathecal Catheters (After Inadvertent Dural Puncture)

  • Overall failure rate: 5.7% in a large retrospective review 1
  • After inadvertent dural puncture specifically: 6.1% 1
  • After intentional dural puncture: 2.8% 1
  • These rates are comparable to standard epidural failure rates 1

Major Risk Factors That Increase Failure Risk

Provider-Related Factors

  • Low-volume specialists have 3.77 times greater odds of inadvertent dural puncture compared to high-volume specialists 1, 4
  • Night shift placement (19:00-08:00) carries 6.33 times higher risk of inadvertent dural puncture, likely due to fatigue and less experienced providers 1, 4
  • Non-obstetric anesthesiologists have 4.6 times higher odds of failed conversion to cesarean anesthesia (OR=4.6,95% CI 1.8-11.5) 3

Patient and Labor-Related Factors

  • Greater cervical dilation increases risk, with each additional centimeter associated with increased failure (OR 1.23,95% CI 1.04-1.42) 1, 4
  • Cervical dilation >7 cm is a strong predictor of inadequate epidural analgesia 2
  • Previous failed epidural significantly predicts subsequent failure 2

Technical Factors During Placement

  • Paresthesia during insertion predicts inadequate analgesia 2
  • Loss of resistance using air (versus saline) increases failure risk 2
  • Difficult insertion is associated with 8.6% incidence and predicts failure 2
  • Increasing number of clinician-administered boluses during labor increases conversion failure risk (OR=3.2,95% CI 1.8-5.5) 3

Urgency-Related Factors

  • Greater urgency for cesarean delivery dramatically increases failure risk (OR=40.4,95% CI 8.8-186) 3

Mechanisms of Epidural Failure

Primary Placement Issues

  • Incorrect identification of epidural space is the most common cause 5
  • Catheter misplacement into incorrect tissue planes 5, 2
  • Tissue compartmentalization within the epidural space 2

Secondary Catheter Problems

  • Catheter migration after initially correct placement 1, 5
    • In 16.3% of failed intrathecal catheters, migration out of subarachnoid space was suspected 1
  • Catheter kinking, occlusion, or disconnection 2
  • Inadequate catheter depth at skin level 4

Pharmacological Issues

  • Inadequate spread of local anesthetic, particularly with intrathecal catheters using low flow rates 1
  • Suboptimal dosing of local anesthetic drugs 5
  • Use of single-orifice catheters (versus multi-orifice) may contribute to uneven spread 1

Critical Safety Considerations

High/Total Spinal Block Risk

  • Incidence: approximately 1 in 4367 cases during spinal anesthesia 1, 6
  • Risk is higher when spinal anesthesia is attempted following failed epidural top-up 1
  • Three high blocks occurred in 761 intrathecal catheter cases (0.4%), all requiring respiratory support 1

Warning signs requiring immediate intervention: 1

  • Increasing agitation
  • Significant hypotension and bradycardia
  • Upper limb weakness
  • Dyspnea or difficulty speaking

Monitoring Requirements

  • Block height must be assessed at least every 5 minutes until no further extension is observed 1, 6
  • Negative aspiration does not guarantee correct placement - occurs in 1 in 1,750 to 1 in 126,000 cases 1

Prevention Strategies

Technical Optimization

  • Use saline for loss of resistance rather than air 2
  • Consider ultrasound guidance in high-risk patients 2
  • Multi-orifice catheters provide more reliable aspiration testing 4
  • Combined spinal-epidural technique may be more reliable as free CSF flow confirms correct midline placement 4, 6

System-Level Interventions

  • Clear catheter labeling is essential to prevent dosing errors 1, 4
  • Structured handover protocols between healthcare professionals, especially during transfer to operating theater 1
  • Avoid high-risk timing when possible (night shifts with less experienced providers) 1, 4

Management of Failed Epidural

When Inadequate During Labor

  • The predictive model correctly classified 96.7% of successful epidurals but only 16.8% of failures, suggesting failure is often unpredictable 2
  • Alternative anesthesia methods must be planned when extension of block is not possible 1
  • Options depend on spread of injectate, urgency of delivery, and provider/patient preferences 1

For Urgent Cesarean Delivery

  • Do not administer repeat full spinal dose without careful consideration - carries 1 in 4367 risk of high/total spinal 6
  • Consider incremental epidural dosing if catheter is properly positioned and tested 6
  • Prepare for conversion to general anesthesia if block cannot be extended adequately 6

References

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Guideline

Causes of Ineffective Epidural Anesthesia

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Research

Failed epidural: causes and management.

British journal of anaesthesia, 2012

Guideline

Failed Spinal Anesthesia: Possible Causes and Management

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Related Questions

What are the guidelines for administering a casual epidural (peridural anesthesia) for pain management?
What are the indications, contraindications, procedure, and potential side effects of epidural anesthesia?
What are the considerations and effects of epidural anesthesia?
What information should be included in epidural procedure notes?
What are the possible reasons for failed spinal anesthesia in a patient who received 2.2ml of 0.5% hyperbaric bupivacaine (local anesthetic) and 300mg diamorphine (opioid analgesic) for a cesarean section, with a sensory block at the T10 level and ability to bend both legs?
What is the recommended treatment regimen for a patient with Heart Failure (HF)?
What is the likely diagnosis for a patient with a nonenhancing, T2-hyperintense lesion in the motor cortex, presenting with progressive fine-motor impairment, tremors, and weakness?
Is the requested procedure with CPT (Current Procedural Terminology) codes 22633, 22840, 63052, 63047, 22853, 20936, and 20930, along with inpatient level of care, medically necessary for a patient with low back pain radiating to the lower extremity and right foot who will undergo L5-S1 posterior lumbar decompression and fusion with TLIF (Transforaminal Lumbar Interbody Fusion) and right L4-5 hemilaminotomy with microdiscectomy?
What is the initial treatment regimen for heart failure with reduced ejection fraction (HFrEF)?
What is the initial treatment for a patient with pneumonia presenting in respiratory distress to the emergency room?
What speeds up arthritis more in the knee, an untreated torn meniscus or a previous meniscus debridement?

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.