What fiber‑optic bronchoscope size should be used to confirm placement of a 39‑French double‑lumen endotracheal tube in an adult?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: February 17, 2026View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Bronchoscope Size for 39-French Double-Lumen Tube Confirmation

For a 39-French double-lumen tube, use a bronchoscope with an external diameter of 4.0 mm or smaller to ensure adequate ventilation and prevent tube or scope damage during placement confirmation.

Critical Size Relationship

The internal diameter of the endotracheal tube relative to the bronchoscope's external diameter is paramount for safe bronchoscopy. 1

  • A 39-French DLT has an internal diameter of approximately 6.5 mm in the bronchial lumen 2
  • A bronchoscope occupying more than 50-60% of the tube's cross-sectional area will compromise ventilation and risk equipment damage 1
  • A 4.0 mm bronchoscope is the maximum safe size, as it occupies approximately 38% of the cross-sectional area of a 6.5 mm lumen 1
  • Smaller pediatric bronchoscopes (3.5-3.8 mm) provide even greater safety margins and are preferred when available 1

Mandatory Bronchoscopic Confirmation

Fiberoptic bronchoscopy is required to verify correct DLT placement even when clinical signs suggest proper positioning. 3, 4

  • Clinical confirmation alone has poor sensitivity and specificity, with malposition occurring in up to 39.5% of cases 3, 4, 5
  • Bronchoscopy must be immediately available even if clinical confirmation is attempted initially 1, 5

Safe Bronchoscopy Technique for DLT Confirmation

Pre-Bronchoscopy Requirements

  • Achieve deep neuromuscular blockade confirmed by peripheral nerve stimulator before inserting the bronchoscope 1, 3, 4
  • Pre-oxygenate with 100% oxygen 1
  • Discontinue ventilation and open the adjustable pressure-limiting valve before disconnecting the circuit 1

Bronchoscopic Verification Steps

  • Confirm the distal end of the bronchial lumen lies above the left upper- and lower-lobe bifurcation 4
  • Visualize the bronchial cuff orientation and right-sided anatomy 3, 5
  • Inflate the bronchial cuff under direct bronchoscopic vision to guarantee proper seal and positioning 3, 4
  • Verify the carina is visible at the appropriate level relative to the tube markings 2

Position Verification After Lateral Positioning

  • Repeat bronchoscopic confirmation after lateral positioning to ensure tube position has not changed 4, 5
  • Lateral positioning causes mean upward migration of 0.92 cm in both tracheal and bronchial directions 4

Critical Safety Considerations

Ventilation Compromise

  • Failure to use an appropriately sized bronchoscope leads to inadequate ventilation, hypoxemia, and potential patient harm 1
  • The ventilator pressure limit should be increased to ensure adequate tidal volumes during bronchoscopy 1
  • Use mandatory ventilation modes rather than triggered modes during the procedure 1

Equipment Damage Risk

  • Oversized bronchoscopes risk impaction or damage to both the scope and the DLT 1
  • Lubrication is essential to facilitate bronchoscope passage and prevent equipment damage 1

Aerosol Generation Prevention

  • Attempting bronchoscopy while ventilating or without adequate neuromuscular blockade creates extremely high aerosol generation risk 1
  • Use HEPA viral filters when disconnecting the circuit 1

References

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Guideline

Double Lumen Tube Sizing

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2026

Guideline

Guidelines for Double‑Lumen Endotracheal Tube Placement and Confirmation

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2026

Guideline

Complications of Double-Lumen Tube Usage in Thoracotomy

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.