What is the recommended depth for endotracheal tube (Ett) placement in adults and pediatric patients?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: January 16, 2026View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Endotracheal Tube Depth Placement

For adults, secure the ETT at 21 cm at the lips for women and 23 cm for men, with the goal of positioning the tube tip 3-5 cm above the carina in the mid-tracheal region. For pediatric patients, calculate the depth using the formula: Depth (cm) = 3 × internal diameter of the tube. 1, 2

Adult ETT Depth Guidelines

The standard depth of 23 cm for men and 21 cm for women at the incisors or lips is the recommended starting point, though this may result in suboptimal positioning in some populations. 1, 3

Key Considerations for Adults:

  • The optimal ETT tip position is 3-5 cm above the carina, placing it in the mid-tracheal region to minimize risks of both endobronchial intubation and accidental extubation. 1

  • Asian populations may require 1 cm less depth: Males should have ETTs secured at 22 cm and females at 20 cm at the corner of the mouth, as the median ETT depth in Asian ICU patients was found to be 22 cm in males and 21 cm in females. 4

  • The standard 21/23 cm method results in 58.5% of ETT tips positioned too closely to the carina (<3 cm above), particularly in women and patients older than 65 years. 5

  • An alternative formula based on patient height may improve accuracy: Depth (cm) = (Height in cm/7) - 2.5. 6

Verification Methods for Adults:

  • Mandatory two-point verification includes visual confirmation (direct visualization of tube passing through vocal cords) and continuous waveform capnography before inducing anesthesia. 1

  • Obtain a chest X-ray in hospital settings to confirm mid-tracheal position and ensure the tip is not in a bronchus. 7, 1

  • Tracheal palpation can improve placement accuracy, with the ETT tip palpable at the sternal notch resulting in 77% correct placements versus 61% with standard depth measurements. 3

Pediatric ETT Depth Guidelines

Calculate the depth of insertion using the formula: Depth (cm) = 3 × internal diameter of the tube, measured at the lip. 2

Specific Pediatric Recommendations:

  • For a 4.5 mm cuffed tube, the calculated depth of insertion is 13.5 cm at the lip. 2

  • The tube tip should be positioned 3-5 cm above the carina in the mid-tracheal region. 2

  • Using the 3× ETT size formula based on the actual tube chosen results in only 75% accurate placement, while using the Broselow tape-suggested ETT size improves accuracy to 85%. 8

  • The commonly used 3× tube size formula results in 15-25% malpositioned tubes, with practitioners able to improve reliability by utilizing the Broselow tape recommendations. 8

Pediatric Tube Size Selection:

  • For infants under 1 year: 3.0 mm ID for cuffed tubes, 3.5 mm ID for uncuffed tubes. 1

  • For children 1-2 years: 3.5 mm ID for cuffed tubes, 4.0 mm ID for uncuffed tubes. 1

  • For children over 2 years: Cuffed tube ID (mm) = 3.5 + (age/4); Uncuffed tube ID (mm) = 4.0 + (age/4). 7, 1, 2

Universal Verification Requirements

Use multiple confirmation methods immediately after intubation, including visualization of bilateral chest rise, auscultation for equal breath sounds bilaterally, confirmation of absence of gastric insufflation sounds, verification of exhaled CO₂ with capnography, and monitoring of oxygen saturation with pulse oximetry (Class I, Level of Evidence B). 7, 1, 2

  • Re-verify tube position after securing the ETT, during transport, and each time the patient is moved. 7, 9

  • Record and document the depth of the tube at the teeth or gums before securing. 9

  • If direct laryngoscopy visualization is uncertain, perform direct laryngoscopy to confirm the ETT lies between the vocal cords. 7

Critical Pitfalls to Avoid

  • Never advance an airway exchange catheter beyond 25 cm in adults, as the distal tip must remain above the carina. 7, 1

  • When using cuffed tubes, monitor and limit cuff inflation pressure to less than 20-25 cm H₂O per manufacturer instructions. 7, 1, 2

  • If an intubated patient deteriorates, immediately assess using the DOPE mnemonic: Displacement of tube, Obstruction of tube, Pneumothorax, Equipment failure. 2, 9

  • Maintain the patient's head in neutral position after securing the tube to prevent tube displacement. 2, 9

  • The standard 21/23 cm depth method is particularly unreliable in women, elderly patients (>65 years), and Asian populations, requiring adjustment. 4, 5

References

Guideline

Endotracheal Tube Size Selection and Management

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2026

Guideline

Endotracheal Tube Management in Children

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2026

Research

Tracheal palpation to assess endotracheal tube depth: an exploratory study.

Canadian journal of anaesthesia = Journal canadien d'anesthesie, 2014

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Research

Prospective assessment of guidelines for determining appropriate depth of endotracheal tube placement in children.

Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies, 2005

Guideline

Securing Endotracheal Tubes

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.